Mercury 230 AM

Mercury 230 AM Mercury 230 AM Mercury 230 AM Mercury 230 AM
Product code: 230 AM

APPLICATION

The meters are designed for single-tariff measurement of active electric energy in three-phase three- and four-wired AC networks. The meters are designed for indoor operation and can be installed in the areas with additional environmental protection (installed inside premises, cabinets or boards).

MODIFICATIONS

The meter modifications are available with different rated voltage, rated and peak current.


Metrological performance

Meter accuracy class (active/reactive)
• transformer connection 0.5S
• direct connection 1
Rated voltage, V
• CT&VT connection 3*57,7 / 100
• CT, direct connections 3*230 / 400
Base/peak current, A
• CT, CT&VT connections 5 / 7.5
• direct connection 5 / 60; 10 / 100
Peak current for direct connection meters during 10 ms 30*I max
Peak current for CT, CT&VT connection meters during 0.5 s 20*I max
Starting current, А
• CT, CT&VT connections 0.005
• direct connection 0.02 / 0.025

REGULATORY COMPLIANCE

GOST R 52320, GOST R 52322, GOST R 52323. State registers of Russia and CIS countries.

Active/total power consumption in each meter voltage circuit at rated voltage, W/V*A 1 / 8
Total power consumed by each current circuit, max, V*А 0.1
Calibration interval, years 10
Warranty period, years 3
Mean time between failures, min, h 140,000
Operating temperature range, °C -40 to +55
Weight, max, kg 1.5
Dimensions (LхWхH), mm 170x74x258

— Digital measurement of electrical energy.

— Energy measurement independently from current circuits phasing (measurement per module).

— Counter with anti-reverse mechanism and magnetic fields protection.


Table of commercially available meters modifications. Other modifications are available on request.

Modification Rated voltage, V Nominal/ maximum current, А Accuracy A/R
Mercury 230 AM-00 3*57,7/100 5(7,5) 0,5S
Mercury 230 AM-01 3*230/400 5(60) 1,0
Mercury 230 AM-02 3*230/400 10(100) 1,0
Mercury 230 AM-03 3*230/400 5(7,5) 0,5S

Meter modification code structure:

Mercury 230 АМ-0Х

А – active energy measurement,
М – electromechanical counter,
– code of rated/peak current and voltage, accuracy class,
Rated/peak currents, voltages and accuracy classes

Code Rated (peak) current, A Rated voltage, V Code Accuracy class
00 5/10 3 x 57.7/100 0.2S/0.5 or 0.5S/1
01 5/60 3 x 230/400 1/2
02 5/100 3 x 230/400 1/2
03 5/10 3 x 230/400 0.2S/0.5 or 0.5S/1