Mercury 230 ART

Mercury 230 ART Mercury 230 ART Mercury 230 ART Mercury 230 ART Mercury 230 ART Mercury 230 ART Mercury 230 ART Mercury 230 ART
Product code: 230 ART

APPLICATION

The meters are designed for unidirectional multi-tariff measurement of active and reactive electric energy and power, as well as electrical parameters in three-phase three- and four-wired AC networks with subsequent accumulated data storage, generation of events and data transfer to the AMR/AMI system’s data collection centers.

The meters are designed for indoor operation and can be installed in the areas with additional environmental protection (installed inside premises, cabinets or boards).

MODIFICATIONS

The meter modifications are available with different rated voltage, rated and peak current, and additional functionalities which are not related to metrological perfomance.

Metrological performance

Meter accuracy class (active/reactive)
• transformer connection 0.5S / 1
• direct connection 1 / 2
Rated voltage, V
• CT&VT connection 3*57,7 / 100
• CT, direct connections 3*230 / 400
Base/peak current, A
• CT, CT&VT connections 5 / 7.5
• direct connection  5 / 60, 10/100
Peak current for direct connection meters during 10 ms 30*I max
Peak current for CT, CT&VT connection meters during 0.5 s 20*I max
Starting current, А
• CT, CT&VT connections 0.005
• direct connection 0.02, 0.04

REGULATORY COMPLIANCE

GOST R 52320, GOST R 52322, GOST R 52323, GOST R 52425. State registers of Russia and CIS countries. 

Active/total power consumption in each meter voltage circuit at rated voltage, W/V*A 2 / 10
Total power consumed by each current circuit, max, V*А 0.1
Supply voltage range of backup power input and interfaces RS-485 and СAN, V 5.5 – 12
Average current consumption from an external power supply of the interface RS-485, CAN, мА 30
Average current consumption by the backup power supply, mA 150
Number of tariffs 4
Data retention during power outage, min, years 10
Calibration interval, years 10
Warranty period, years 3
Mean time between failures, min, h 150,000
Operating temperature range, °C -40 to +55
Weight, max, kg 1.5
Dimensions (LхWхH), mm 170x74x258

— The meter measures, stores, displaying on LCD and communicate information via different interfaces of active and reactive electrical energy independently by every tariff zone and cumulatively for all tariff zones for the following periods of time:

  • total cumulative energy;
  • energy at the beginning of the current day and the previous day;
  • energy at the beginning of the current month and 11 previous months;
  • energy at the beginning of the current year and the previous year;
  • consumption for the current day and the previous day;
  • consumption for the current month and 11 previous months.

— Energy measurement independently from current circuits phasing (measurement per module).

— TOU with the option of setting individual schedule for every day of the week based on 4 tariffs, 16 time zones per day. Individual tariffs schedule is set every month. Minimal interval of each tariff during 24 hours is 1 minute. Multi-tariff per-phase metering function.

— Measurement of technical losses in power lines and power transformers.

—Measurement of electrical network parameters.

  • instantaneous values of active, reactive and total power per each phase and the total of all phases with the total power vector direction indication;
  • RMS of phase currents and voltages ;
  • phase angles values;
  • power frequency;
  • power factors of each phase and of their sum.

— Power profile and technical losses power profile with arbitrary integration period from 1 to 45 minutes. The storage period is 85 days for 30 minutes averaging time.

— Recording of morning and evening peaks of active and reactive power at a specified interval with a monthly schedule.

— Event logging including power quality events.

— External backup power supply.

— Multifunctional pulse outputs including load control function.

— Automatic self-diagnosis with error indication.

— Nonvolatile electronic crimped seal.

—Recording of unauthorized impacts to the indelible event log.


Table of commercially available meters modifications. Other modifications are available on request.

Modification Rated voltage, V Nominal/ maximum current, А Accuracy A/R Interfaces, relay
Mercury 230 ART-00 С(R)N 3*57,7/100 5(7,5) 0,5S/1,0 CAN (RS-485)
Mercury 230 ART-01 С(R)N 3*230/400 5(60) 1,0/2,0 CAN (RS-485)
Mercury 230 ART-02 С(R)N 3*230/400 10(100) 1,0/2,0 CAN ( RS-485)
Mercury 230 ART-03 С(R)N 3*230/400 5(7,5) 0,5S/1,0 CAN (RS-485)
Mercury 230 ART-00 PQRSIDN 3*57,7/100 5(7,5) 0,5S/1,0 IrDA, RS-485
Mercury 230 ART-01 PQRSIN 3*230/400 5(60) 1,0/2,0 IrDA, RS-485
Mercury 230 ART-02 PQRSIN 3*230/400 10(100) 1,0/2,0 IrDA, RS-485
Mercury 230 ART-03 PQRSIDN 3*230/400 5(7,5) 0,5S/1,0 IrDA, RS-485
Mercury 230 ART-01 СLN 3*230/400 5(60) 1,0/2,0 CAN, PLС-I
Mercury 230 ART-02 СLN 3*230/400 10(100) 1,0/2,0 CAN, PLС-I
Mercury 230 ART-03 СLN 3*230/400 5(7,5) 0,5S/1,0 CAN, PLС-I

Meter modification code structure:

Mercury 230 ART-0X P Q R (C I L) S D N

А – active energy measurement,
R – reactive energy measurement,
T – tariffs (TOU),
– code of rated/peak current and voltage, accuracy class,
Rated/peak currents, voltages and accuracy classes

Code Rated (peak) current, A Rated voltage, V Code Accuracy class
00 5/10 3 x 57.7/100 0.2S/0.5 or 0.5S/1
01 5/60 3 x 230/400 1/2
02 5/100 3 x 230/400 1/2
03 5/10 3 x 230/400 0.2S/0.5 or 0.5S/1
P – profile, events log, technical losses recording and other additional functions,ended program functions,
Q – power quality measurement,
R – interface RS-485 (С – CAN, I – IrDA, L – PLC-I),
S – internal power supply for RS-485 interface,
D – power backup input,
N – electronic seal.